or XLT (Touch Screen) Series
Specifically designed
for a large stamping press manufacturer, this PC had to combine floating
suspension for shock, special heat dissipation and monitoring and front
access for rapid exchange of all parts and
boards.
|

1 of the 4 shock absorber
for the housing
|
Metal wire shock absorbers float the housing
and the hard drive is additionally protected with rubber shock
absorbers.
Five fans are temperature controlled and
speed monitored.
If one fan does not work properly, a red LED on the front panel
indicates fan failure. Further, the slot CPU is temperature monitored
with another red LED on the front panel. This warns of potential
heat failure before it occurs.
Service and short downtime considerations did not end with the front
door access. Power supply, hard drive, floppy, CD-Rom, etc. have quick
mounting frames or supports and sufficient access space. For
instance the two screen back lights or display are exchanged in less
than one minute - not hours.
A separate front door
gives access and covers CD-ROM, floppy, mouse and keyboard.
This combination
makes the PC suitable for your toughest application !!
Typically use:
|
Technical
Data
|
|
Slot-CPU*:
|
AMD K2/6 300MHZ or Pentium
233 MMX
|
RAM*:
|
128 MB
|
Display:
|
15.1” (1024 x 768) color
active matrix TFT LCD flat panel
|
Slots ISA/PCI*:
|
4 PCI, 8 ISA 2 combination
ISA & PCI
|
Drives:
|
2.5” IBM Hard Drive,
Floppy-Disk, CD-ROM
|
Interfaces:
|
Serial & SCSI (front
access), Parallel
|
Ethernet:
|
3 Com Ethernet controller
card 10/100 RJ-45 and AUI
|
Fans (Housing):
|
4 long life fans,
temperature controlled and speed monitoring
|
CPU Fan:
|
|
Power Supply:
|
24V DC, 80-240 VAC
|
Power Consumption:
|
240 Watt
|
Operating System:
|
Win NT 4.0, (Dos 6.22, Win
3.11, Win9x, Win2000)
|
|
Analog resistive
|
|
Finger mouse
|
|
|
Environment
|
|
EMC:
|
EN 61000-4-2 (IEC-801-2) /
EN 61000-4-4 (IEC-801-4)
|
Operating Temperature:
|
32 – 131°F (0-55° C)
|
Storage Temperature:
|
-4°F – 176°F (-20 –
80°C)
|
Humidity:
|
98% (No condensation)
|
Front Door:
|
NEMA 12 (IP65) closed Front
Door
|
Standards:
|
CE
|
|
|
Dimension
|
|
Width:
|
19”
|
Height:
|
15.7”
|
Deep:
|
7.2”
|
|
|
Shock /
Vibration
|
|
Vibration (50 to 2000 Hz)
|
£
1 g
|
Shock (11ms) IEC 68-2-27
|
£
10 g
|
* Check for the latest
update
|
back